Jack A6F Kataloğu — Sayfa 19
Ach uP Safety switch alarm Adjust the machine to the correct position. 3.4 Error mode Ifthe error code appears, please check the following items first: 1.Make sure the machine has been connected correctly; machine head. 2. Confirm that the control box match with the 3. Confirm factory reset is accurate Error Code Description Solution Err-04 Hardware over current__| Turn off the power switch, and restart after 30 seconds. If the controller still does not| Err-02 Software over current work, please replace it and inform the manufacturer. Disconnect the power to the controller; check the input power supply voltage is low or| not (less than 176V). If the power supply voltage is low, please start the controller after] Err-03 Under-voltage recovers the voltage. If the controller still does not work, please inform the manufacturer and replace the controller. Err-04 Over-voltage when the | Disconnect the controller power and check if the input voltage is too high (higher than re machine is off 264V). If yes, please restart the controller when the normal voltage is resumed. If the controller still does not work when the voltage is at normal level, please replace the| Err-05 Over-voltage in operation controller and inform the manufacturer. Turn off the system power. Check carefully, if the solenoid connection is loose or| Err-06 Solenoid circuit fault damage, please change it in time. Then restart the system after confirmation, if it still does not work, please inform the manufacturer and replace the controller. Err-07 Motor current measuring | Turn off the system power, restart after 30 seconds to see if it works well. If such failure, re failure happens frequently, seek technical support. Turn off the system power. Check whether the motor power input plug is off, loose or| broken, or there is something tangled on the machine head. Please make them correct Err-08 Sewing motor blocked then restart the system. If it still does not work, please inform the manufacturer and replace the controller. Turn off the system power. Check carefully, if white braking resistor connector on the} Err-09 Brake circuit fault power board is loose or fall off, please plug it tight then restart the system, if it still does} not work, please inform the manufacturer and replace the controller. Check carefully, if the connection between the control panel and controller is off, loose, Err-10 Communication failure or broken, please make it correct then restart the system, if it still does not work, please inform the manufacturer and replace the controller. Check if the connection line between machine head synchronizer and controller is| Machine head needle Err-11 loose or not, restore it and restart the system. If it still does not work, please replace the| positioning failure controller and inform the manufacturer. Erre42 Initial motor electrical angle | -Try 2 to 3 more times after power down re failure -_if it still does not work, please replace the controller and inform the manufacturer. Turn off the system power, check if the motor sensor plug is loose or dropped off, Err-13 Motor HALL failure restore it and restart the system. If it still does not work, please replace the controller] and inform the manufacturer. 1/8
| Stok Kodu | Seç |
|---|