Over-voltage when the Disconnect the controller power and check if the input voltage is too high (higher than failure Err-04 machine is off 264V). If yes, please restart the controller when the normal voltage is resumed. If the controller still does not work when the voltage is at normal level, please replace the Err-05 Over-voltage in operation controller and inform the manufacturer. Turn off the system power. Check carefully, if the solenoid connection is loose or Err-06 Solenoid circuit fault damage, please change it in time. Then restart the system after confirmation, if it still does not work, please inform the manufacturer and replace the controller. Err-07 Motor current measuring | Turn off the system power, restart after 30 seconds to see ifit works well. If such failure rr- failure happens frequently, seek technical support. Turn off the system power. Check whether the motor power input plug is off, loose or broken, or there is something tangled on the machine head. Please make them correct Err-08 Sewing motor blocked then restart the system. If it still does not work, please inform the manufacturer and replace the controller. Turn off the system power. Check carefully, if white braking resistor connector on the Err-09 Brake circuit fault power board is loose or fall off, please plug it tight then restart the system, if it still does not work, please inform the manufacturer and replace the controller. Check carefully, if the connection between the control panel and controller is off, loose, Err-10 Communication failure or broken, please make it correct then restart the system, if it still does not work, please inform the manufacturer and replace the controller. Check if the connection line between machine head synchronizer and controller is Machine head needle Err-11 loose or not, restore it and restart the system. If it still does not work, please replace the positioning failure controller and inform the manufacturer. Err-12 Initial motor electrical angle | -Try 2 to 3 more times after power down rr- failure - ifit still does not work, please replace the controller and inform the manufacturer. Turn off the system power, check if the motor sensor plug is loose or dropped off, Err-13 Motor HALL failure restore it and restart the system. If it still does not work, please replace the controller and inform the manufacturer. DSP Read/Write EEPROM Err-14 failure Err-15 Motor over-speed protection Turn off the system power, restart the system after 30 seconds, if it still does not work, Err-16 Motor reversion : please replace the controller and inform the manufacturer. HMI ReadANrite Err-17 EEPROM failure Err-18 Motor overload Turn off the system power. Check whether the motor power input plug is off, loose or Err-23 Motor blocked encoder broken, or there is something tangled onthe machine head. Please make them correct rr- then restart the system. If it still does not work, please inform the manufacturer and replace the controller. 4 Pedal sensitivity adjustment 7/8
| Stok Kodu | Seç |
|---|